This article documents how a PyPSA network becomes an energyRt model: which component becomes which object, where a slot’s value comes from, and the four places where the two representations do not correspond one to one.
It describes the conversion behind the shipped models. Reading it is
not required to use them — vignette("reneuro") covers that
— but it is what you need to check a converted number against its
source, or to decide whether a question the model answers is one the
translation supports.
Scope is the electricity-only network at the
base_s_{clusters}_elec.nc cut point: after the network is
built, before policy overlays and temporal averaging are applied.
The component table
| PyPSA | energyRt | |
|---|---|---|
Bus carrier |
commodity |
bus carriers only — see below |
Load |
demand |
series in @demand, one row per region and
timeslice |
Generator |
technology (+ supply) |
one object per carrier, regions in a
region column |
Generator p_max_pu
series |
weather |
kept out of the technology object |
StorageUnit |
storage |
one object; duration from
max_hours
|
Store + two Links |
storage |
one object with three part capacities |
Line (AC) |
trade |
transport, not Kirchhoff — see below |
Link (DC) |
trade |
transport, faithful |
StorageUnit inflow
|
commodity + supply +
storage + technology
|
four objects — see below |
Everything below is a case where that one-line summary is not the whole story.
carrier names two different things
PyPSA’s carrier field is used for two purposes, and only
one of them is a commodity:
- on a bus it names the energy flowing there —
AC,H2,battery— and that is a commodity; - on a generator or link it names
the technology or the fuel —
CCGT,onwind,battery charger— and that is not.
So commodities are taken from bus carriers, and generator carriers
become technology names. The carriers component itself is a
lookup table of attributes, not a set of objects to create.
Generators carry their fuel explicitly
In an electricity-only network a generator has no fuel bus:
marginal_cost already folds fuel price divided by
efficiency into one number. Translating that literally gives an
output-only technology — a CCGT that consumes no gas. It is
arithmetically equivalent, but it cannot carry a fuel price, a resource
limit, or an emission factor.
Thermal carriers therefore get an explicit fuel @input
with combustion = 1 and the efficiency in
@ceff$cinp2use. CO₂ then follows from the fuel’s carbon
content on the commodity, rather than from a coefficient on the
technology.
The fuel supply is priced at zero and varom
keeps the whole marginal_cost. The fuel price is
not recoverable from the network file, and charging the supply as well
would count it twice. This is the one place in the translation where
double counting could enter.
Capacity depends on whether the generator is extendable:
| PyPSA | energyRt |
|---|---|
| not extendable |
@capacity$stock — exogenous, no capital charged |
| extendable |
@capacity$cap.lo / cap.up — built and paid
for |
Storage: two shapes in, one shape out
PyPSA has two storage representations and a network may use both:
-
StorageUnit— one component carrying a power ratingp_nom, a durationmax_hours, and a round trip split intoefficiency_storeandefficiency_dispatch. -
Store+ twoLinks — an energy reservoir on its own bus, plus a charger and a discharger that carry the conversion efficiencies and their own ratings.
Both become one energyRt storage,
because a storage has three independent capacity variables — charge,
discharge and reservoir — so the second shape needs no extra
objects:
stg <- getObject(pypsa_eur_5, class = "storage")[["STG_BATTERY"]]
grep("^(inp|out|stg)\\.stock$", names(stg@capacity), value = TRUE)
#> [1] "out.stock" "inp.stock" "stg.stock"
stg@seff[, c("stgeff", "inpeff", "outeff")]
#> stgeff inpeff outeff
#> 1 NA 0.9797959 0.9797959inp.* is the charger, out.* the discharger,
stg.* the reservoir, and @seff carries the two
conversion efficiencies plus standing loss. A converted model contains
no separate charger or discharger technologies.
Transmission is a transport model
PyPSA is a hybrid: Kirchhoff’s voltage law applies to the AC
Lines, which form sub-networks and receive cycle
constraints, while DC Links are free transport. energyRt’s
trade is transport throughout.
The consequence is asymmetric and worth stating plainly:
- DC links translate faithfully — a controllable branch is what a transport model represents natively.
- AC lines are a relaxation. The converted model’s AC flows are less constrained than the source, so its objective is a lower bound, and it should not be used to draw transmission-expansion conclusions.
energyRt::newACLine() with kvl = TRUE at
interpolation restores the cycle constraints where that matters.
Capacity belongs to the trade object rather than to a route, so each
bus pair becomes its own object and parallel lines on a pair are merged
by summing s_nom — indistinguishable in a transport model
in any case.
Quadratic AC losses are linearised. The default gives each corridor
one flat teff evaluated at a chosen loading;
tranches = n splits it into n equal capacity
tranches with rising loss rates instead, approximating the curve without
integer variables. Tranches were the default once, which is why
pypsa_eur_5 still carries six of them – at continental
scale they cost a generated constraint per corridor, tranche and
timeslice, which is why the larger models are flat.
Availability leaves the technology object
PyPSA keeps availability in two places at once. p_max_pu
is a static column, and generators_t.p_max_pu is a series
covering the weather-driven generators only. For every generator that
has a series the static value is exactly 1, a placeholder — so reading
the static column alone would make every wind farm permanently
available.
energyRt keeps the bulk series out of the technology: a
weather object holds region × timeslice values and the
technology references it by name.
Hydro inflow becomes four objects
storage_units_t.inflow has no direct equivalent — an
energyRt storage can be charged from a commodity, but not from an
exogenous series. A hydro reservoir therefore decomposes:
| object | role |
|---|---|
commodity HYDWAT
|
virtual reservoir energy, balanced hourly |
supply SUP_HYDWAT
|
availability follows the inflow series |
storage STG_HYDRO
|
the reservoir |
technology E_HYDRO
|
HYDWAT → electricity at the dispatch efficiency |
Conventions that differ
Two conventions produce correct-looking numbers that mean different things, and both are places to check before comparing against a source model.
Rating side. A Link’s
p_nom is rated on its input bus; an energyRt capacity is
rated on activity, i.e. output. Converting one to the other scales by
the efficiency: capacity = p_nom * eff, and
invcost = capital_cost / eff.
Cost annualisation. Where capital_cost
is already annuitised it maps to @invcost$eac, not to
invcost — supplying it as invcost would
annuitise a second time.
Revised assumptions
Everything above translates PyPSA-Eur faithfully — same data, same assumptions, verified against the source model’s own solutions. Three assumption families are also revised, in model versions built beside the faithful one so the two can be solved side by side and the difference read as the effect of the assumption, never of the translation. The revised versions are not among the eleven models the package ships today: they arrive with the repository update and ship as separate data.
Capacity factors
PyPSA-Eur offers each region’s whole eligible area at one blended, best-cells-weighted profile: all the land at the quality of the good sites. The revised layer replaces the blended VRE generators with resource clusters split into quality tiers — wind calibrated to the Global Wind Atlas along an aggregate park power curve, solar levels carved from the Global Solar Atlas — so capacity buys the tier it occupies, with the area each tier actually has. Fixed-tilt panels use a per-location optimal angle (measured effect vs the flat 35°: about zero in Europe — the change is kept for consistency with the atlas assumptions), and single-axis tracked and two-axis tracked variants compete alongside fixed panels at their own capacity factors, packing densities and costs. The construction is documented in the wind energy and solar energy articles.
Economic retirement
The overnight convention treats the existing fleet asymmetrically: non-extendable capacity survives to the planning year whole and free, while extendable carriers are implicitly retired in full and must be rebuilt at least to today’s size. The revised version replaces both halves with one consistent rule set:
- Long-lived, non-replicable assets — nuclear, geothermal, and the hydro chain (reservoir, run-of-river, pumped storage’s sibling dam) — keep their capacity with no investment option, paying explicit fixed O&M.
-
Everything else in the fleet can retire
economically. Fixed O&M is split out of PyPSA’s
capital_costannuity (which includes it), so the solver may retire capacity whose O&M exceeds its value (optimizeRetirement), and new builds pay the pure annuity plus the same O&M without double-counting. The fossil floors are gone: existing gas is free stock that can retire, not a rebuild obligation. -
Carbon-free floors stay. Wind, solar and offshore
keep
cap.lo= today’s capacity — a no-backsliding assumption — and pumped-hydro and battery storage join them, rebuilt at the cost table’s annuities. Reinvested capacity lives its technology lifetime.
Demand
The measured 2025 load is a level, not a forecast: solved against
2050 costs it understates what a 2050 system must build. The revision
keeps the measured hourly shapes and levels at 2025 and grows them by
the TYNDP 2024 scenarios (ENTSO-E/ENTSOG, CC-BY 4.0):
National Trends+ (national plans; extrapolated beyond its 2040 horizon),
and the carbon-neutrality pathways Distributed Energy and Global
Ambition, which follow the National Trends path to 2030 and then diverge
— the scenarios’ own construction. Growth factors are per country and
milestone year (tyndp_demand), anchored so 2025 equals the
measured load exactly; countries the TYNDP perimeter lacks take the
average factor, marked as such. scale_demand() applies a
scenario to any shipped model — one year for an overnight solve, all
milestones for the multi-year models.
What the translation does not do
The conversion reports rather than repairs. A parameter that cannot be represented is named and its entity excluded; it is never replaced with a plausible value. The register travels with each model:
See also
-
vignette("reneuro")— using a shipped model -
vignette("about")— how each model was built, and the licences -
vignette("data")— the region datasets and their aggregation rules